Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-580DS1-BD (DS1 Interface Circuit Pack)
10
ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more of
the following symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of the trunks for this circuit pack are placed into the out of
service state. The system will try to restore the circuit pack within 15
minutes. When no faults are detected for 15 minutes, the DS1 interface
circuit pack is restored to normal operation. All of the trunks for the DS1
interface circuit pack are then returned to the in service state.
Hyperactivity is often caused by the associated facility. In such a case,
faults (such as slips, misframes, or blue alarms) would be entered in the
error log. In addition, many hardware errors would be logged against
the associated trunk circuits. If the facility is OK and the error occurs
again after 15 minutes, replace the circuit pack.
FAIL DS1 Interface circuit pack failed the CSU Repeater Loopback Test.
1. Retry test ds1-loop PCSS ds1/csu-loopback-tests.
2. If the RLB test continues to fail, and the CSU Equipment Loopback Test
(#1210) passed, then replace the CSU Module.
PASS The RLB test executed successfully. The test pattern was transmitted and
received successfully over the connection from the TN767E DS1 board to the
far-edge of the 120A1 CSU Module.
Table 10-161. TEST #1211 CSU Repeater Loopback Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page