DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-30Software Upgrade
5
2. Enter n in the
Alarm Origination
field and press Enter.
3. For some releases of system software, disable
Cleared Alarm Notification
and
Restart Notification
before submitting the form.
!
CAUTION:
Disabling alarm origination prevents the system from generating
alarms, thus preventing unnecessary trouble tickets.
Save Announcements
1. If the system is equipped with a TN750/B Announcement circuit pack,
enter display announcements, and press
Enter. If administered recorded
announcements are listed, enter save announcements [from PCSS] and
press
Enter. Where P is the port network number (1 for PPN, and 2-4 for
EPN), C is the carrier designation (A, B, C, or D), and SS is the number of
the slot in which the circuit pack resides (01 to 21).
NOTE:
If multiple TN750/B circuit packs are present, you
must
specify the
slot location for the save announcements command. If there is only
one announcement circuit pack, the system defaults to the proper
location.
NOTE:
The TN750C Announcement circuit pack contains on-board
non-volatile memory. It is not necessary to back up a TN750C.
Shut Down DEFINITY LAN Gateway System
If a DEFINITY LAN Gateway system resides in the control cabinet to be
upgraded, prepare to shut down the DEFINITY LAN Gateway assembly and
allow the disk to completely spin down.
!
CAUTION:
Save the system parameters if you plan to reuse the current system.
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before
powering down the system cabinet where it resides can damage the LAN
Gateway disk.
1. Log onto the DEFINITY LAN Gateway.
See the DEFINITY Communications
System Generic 3 Installation, Administration and Maintenance of
CallVisor ASAI over the DEFINITY LAN Gateway
, 555-230-223, for the
procedure to log on.