DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-276CARR-POW (Carrier Port Power Unit) for AC-Powered Systems
10
Power Unit Query Test (#127)
This test queries the Maintenance/Tape Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a system with High or Critical
Reliability, or the EPN Maintenance circuit pack in an EPN multicarrier cabinet
system for the status of pair of power units in the specified carrier. If both power
units are on and functioning, then the test passes. If both are not on and
functioning, it fails.
PASS Both power units in the recycled carrier were
found to be healthy by the Maintenance/Tape
Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a
system with High or Critical Reliability, or the EPN
Maintenance circuit pack in an EPN multicarrier
cabinet system after the power units were
powered down and back up. If the status LEDs on
both power units are not showing green, then the
PR-MAINT (Maintenance/Tape Processor),
DUPINT (Duplication Interface) circuit pack, or the
EPN MAINT (Maintenance) circuit pack may have
incorrectly reported the state of the power units.
Look for and resolve any alarms on these MOs.
Table 10-83. TEST #127 Power Unit Query Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not
available.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-82. TEST #126 Power Unit Recycle Test — Continued
Error Code
Test
Result Description/ Recommendation
Continued on next page