Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-111display communication-interface
8
Output for Processor-Channel Object
The following display shows a typical result for display comm proc.
Proc Chan The Processor Channel denotes one of the processor channels
on the processor link. With this link/logical channel pair and the
one specified in the interface link and interface channel field, a
network channel to a remote machine is specified. The valid
range for link is 1 to 16, specifying one of the 16 interface links.
Each interface link corresponds to a port on a PGATE board.
The Processor channel is not administrable.
Application This field specifies the type of application that connects to this
processor channel. The following lists the valid entries:
Interface Link The interface link to which the processor channel is connected.
Interface Chan The channel on the interface link to which the processor
channel is connected.
Local Port The switch application port used by the local session.
Remote Port The application port used by the remote session.
Adjunct Name The name of the adjunct connected to this processor channel.
These are defined in the Adjunct Name Form. Only AUDIX and
MSA channels (AUDIX, MSAAMWL, MSAHLWC, MSALLWC,
and MSAMCS) require entries in this field.
Machine-ID This is the network machine ID for the remote machine. Machine
IDs are required only for the AUDIX adjunct and DCS
connections.
display communication-interface processor-channels Page 1 of 8
PROCESSOR CHANNEL ASSIGNMENT
Proc Interface Local Remote Adjunct
Chan Application Link Chan Port Port Name Machine-ID
1: dcs 3 1 1 1 13
2: audix 1 1 59 11 AUDIX1 1
3: audix 2 1 59 11 audix2 2
4: gateway 1 10 59 10
5: gateway 1 9 59 9
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16: