DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-572test ds1-loop
8
If the "inject-single-bit-error" parameter is selected, but no CPE Loopback Jack,
far-end CSU, or one-way span test is active on the DS1 circuit pack, then the
following message will be displayed:
Parameter valid only if a loopback/span test is active on the DS1
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the board in cabinet 1, carrier c,
slot 7 is a TN767E DS1 board. The command that was entered was "test ds1-loop
1c07."
Feature Interactions
Loopback or span tests will not be allowed on DS1 boards unless the board has
been busied out.
Only one of the CPE Loopback Jack, far-end CSU, one-way span, or DS1/CSU
loopback tests may be active at any given time on a DS1 span.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the maintenance object.
Test No The actual test that is being executed.
Result The result of the individual test - "PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD".
Error Code A system-generated number that tells why the release failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test ds1-loop 01C07 ds1/csu-loopback-tests
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 DS1-BD 1209 PASS
01C07 DS1-BD 1210 PASS
01C07 DS1-BD 1211 PASS
Command Successfully Completed