DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1119PMS-PRNT/JNL-PRNT (PMS Printer Link)
10
data module, and the printer device. Enter status data <extension> and
verify that the data extension of the printer device is in the in-service/idle
state. If the data extension is not available, then refer to the ‘‘
Procedures
for Restoring the PMS Printer Link’’ section for resolution.
d. Link idle timer; link comes down. This error indicates that the printer
device is in an off-line state, for example, paper jam or paper out for a
printer device. Check the printer device and act promptly to put it back to
on-line state. Enter test journal wakeup-log|pms-log command to set up
the printer link.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Link
Retry Test
, for example, you may also clear errors generated from other tests in
the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external
printer device. If the link has been disconnected already, this test just returns
PASS. All resources allocated for a PMS Printer Link are released after this test.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND
Table 10-330. TEST #213 Link Tear Down Test
Error
Code
Test
Result Description/ Recommendation
40 ABORT Internal system error
50 ABORT Internal system error
1. Retry the command at 1minute intervals a maximum of 5 times.