Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-199BRI-SET, ASAI-ADJ, BRI-DAT
10
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system and deciding which ones to address,
always investigate errors associated with the circuit pack and port first. Clearing
these error codes first may also clear errors generated against the endpoint.
When all circuit pack and port errors have been cleared, and errors still exist
against the endpoint, always investigate errors in the order they are presented in
58 Bearer
Capability Not
Presently
Available
Requested bearer capability is implemented, but
not administered. No B-channel administered. See
recommendation 50 above.
SERVICE OR
OPTION NOT
IMPLEMENTED
65 Bearer Service
Not
Implemented
Requested service not implemented in switch or
endpoint.
69 Requested
Facility Not
Implemented
Requested service not supported in switch or
endpoint.
1. Consult switch and endpoint documentation to
determine service support.
2. If Step 1 does not resolve the problem, escalate
to the next tier.
ADJUNCT/SWI
TCH ERROR
CONDITIONS
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between
the switch and the adjunct. See the CallVisor
protocol reference manual.
2. If step 1 does not resolve the problem, escalate
to the next tier.
Table 10-65. ISDN-BRI Cause Values — Continued
Code Explanation Recommendation
Continued on next page