DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-991OPS-LINE (DS1 OPS Line)
10
1020 ABORT The test did not run due to an already existing error on
the specific port or due to a more general error on the
circuit pack.
1. Examine the error log for existing errors against this
port or the circuit pack and attempt to diagnose the
already existing error. (Error code 1793 indicates a
problem with the DS1 interface board, and any
problems on the associated DS1-BD or UDS1-BD
should be resolved first.)
2000 ABORT The test was aborted because response to the test was
not received within the allowable time period.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test aborts with error code 2000 again, run
short test sequence on the associated DS1-BD or
UDS1-BD. If tests 138 through 145 on the
associated DS1-BD or UDS1-BD are also aborting
with error code 2000, hyperactivity on the board or
facility is indicated. In this case, the hyperactivity
problem should be dealt with first.
3. If the test continues to abort, escalate the problem.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-286. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page