DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-687upgrade software
8
If the SPE-select switches are thrown to prevent the SPE-interchange during a
software upgrade, the following message is displayed:
SPE select switches thrown; upgrade complete only on standby
If the standby SPE is not in the standby mode and is busy running tests, the
following message will be displayed:
Standby SPE busy with another task;
for information use ’status system’
If the standby SPE has not completed initialization, the following message will be
displayed:
Standby SPE memory not refreshed; Use ’refresh spe-standby’
If the active SPE cannot communicate with the standby SPE after the standby
SPE is properly upgraded, the following message will be displayed:
Upgrade failed; no communication with
standby after new software booted
If the SPE-interchange failed and the new software cannot be run in the active
SPE, the following message is displayed:
Software upgrade failed, could not perform an interchange
Output
The following is the output of a successful simplex upgrade upon entering the
"upgrade software" command:
INITIATING SOFTWARE UPGRADE
MEM-CARD CHECKSUMPASSED
REPROGRAMMING MTPPASSED
ERASING MEMORYPASSED
REPROGRAMMING SPEPASSED
FLASH TEXT CHECKSUM PASSED
UPGRADE COMPLETE
<beep>
REPLACE SOFTWARE MEM-CARD WITH TRANSLATION MEM-CARD
<beep>