DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-62change system-parameters maintenance
8
Packet Bus
Activated
Enables the system Packet Bus.
If this field is set to ‘‘yes'', then maintenance software assumes that
there is a Packet Control circuit pack installed in the system. The
packet endpoints (for example, ASAI, and/or BRI) may be
administered, and maintenance testing runs on both the Packet
Control circuit pack and on the Packet Bus (This field should be set to
“yes” after a packet control circuit pack is installed.). If a Packet
Control circuit pack is not installed in the system, then a major alarm
is raised against the PKT-CTRL MO.
This field can only be changed from ‘‘yes'' to ‘‘no'' if there are no
packet endpoints administered, thus ensuring that there can be no
packet endpoints administered if the packet bus is not activated.
This field should be set to “yes” after a Packet Control circuit pack is
installed.
If a Packet Control circuit pack is not installed, then this field should
be set to ‘‘no'' (the only exception is when setting up translations for a
system for which not all of the required hardware is available). (no)
Customer
Access to
INADS Port
Provides the capability to prohibit access to system administration and
maintenance interface, via the INADS port when using customer login
ID’s. This field can only be activated by Lucent Technologies services
through system-parameters maintenance administration.(no)
Repeat Dial
Interval
(MMS)
Indicates the number of minutes that the system must wait before
attempting another call origination to an OSS. This timer is triggered by
the lack of a far-end acknowledgment.