DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-165enable synchronization-switch
8
Output
The command returns one of the following messages:
1. If the time-out duration is not between one and 72:
XX is an invalid identifier; please press HELP
2. If the port or board specifier is not valid:
Port/Board invalid
3. If the Suspend Alarm Origination table is full:
Table full; cannot enable a new entry
Feature Interactions
None.
enable synchronization-switch
This command re-enables automatic clock switching.
Synopsis
enable synchronization-switch
Permissions
The following default logins may execute this command: system technician,
inads, init.
Examples
enable synchronization-switch
Description
The enable synchronization-switch command puts the automatic clock switching
capability of the maintenance subsystem back into a normal state. Clock refers to
the oscillator on a tone/clock or DS1 interface.
The synchronization subsystem provides error free digital communication
between the switch and other PBXs, COs, or customer premise equipment. The
subsystem is made up of system components involved in synchronization: TDM
bus clock, DS1 trunk board, maintenance and administration software resident in
the SPE.