Maintenance Object Repair Procedures
Page 10-1071PI-PT (Processor Interface Port)
10
Standby Processor Interface Port Test (#404)
This test is the same as Test #182 in the Processor Interface Link (PI-LINK)
Maintenance documentation. However, this test only runs on the Standby
Processor Interface circuit pack. It is an on-board loop around test. This test
checks the health of physical port on the circuit pack. If the test fails, then a Major
alarm is raised on the circuit pack. When the circuit pack is put into local loop
around mode, frames are looped internally on the circuit pack. If the test fails, the
Processor Interface circuit pack reports the failure. It is a good check of most of
the working hardware on the Processor Interface circuit pack.
Table 10-312. TEST #404 Standby Processor Interface Port Test
Error
Code
Test
Result Description/Recommendation
2
9
16
80
84
85
93
94
102
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1124 ABORT The PI link for this port is currently disabled. This test does not run on
disabled PI links.
1. Retry this test if the PI link is re-enabled. Enter the display
communication-interface link command to verify that this link has
been disabled.
1125 ABORT The Processor Interface Loop Around Test on this port could not be
executed since the Processor Interface circuit pack is not in the correct
state.
1. Check PI-BD for possible errors and resolve them first.
2. Rerun the test interface PCS sh command.
3. If the test continues to abort while the PI-BD Test (#423) passes,
escalate the problem.
Continued on next page