Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-25busyout pms-link
8
Output
For the following output example, the command busyout packet-control 1A was
entered.
Feature Interactions
In a duplicated system, an attempt to busyout the packet-control that resides in
the standby processor complex will be disallowed.
When the packet-control in the active control complex is busied out, all
connectivity across the Packet Bus will be severed. Thus, all ISDN-BRI
point-to-point signaling links that have been established via the active
packet-control will be torn down by the busyout packet-control command. The
release packet-control command will reestablish all Packet Bus connectivity.
busyout pms-link
This command will busyout a specified property management system link.
Port This field represents the Cabinet-Carrier in which the
Packet-Control resides.
Maintenance Name The type of maintenance object that is being busied out ( which in
this case is always PKT-CTRL).
Alt. Name This field is not used in this output display.
Result An indicator as to whether the object was successfully busied out
( "PASS," "ABORT," or "FAIL").
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes is present in the
"Busyout/Release Error Codes" section of this chapter.
busyout packet-control 1A SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
1A PKT-CTRL PASS
Command successfully completed