DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1020PDMODULE, TDMODULE (Data Module)
10
Table 10-292. TEST #175 Data Module Internal
Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT Could not get translation information for port.
1. Verify that port circuit is administered.
2. Wait one minute and attempt the test again.
3. If the test continues to abort and the port is not in
use, escalate the problem.
1005 ABORT This test is not applicable to the given hardware
configuration.
1. This abort message can be ignored.
1020 ABORT Internal Software Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1030 ABORT Internal software group identifier for data module not
valid.
1. Verify that port circuit is administered correctly.
2. If administration data correct, escalate the problem.
1031 ABORT Extension number not valid.
1032 ABORT Extension number not correct length.
1. Verify that the data module extension is administered
correctly.
2. If the administration data is correct, escalate the
problem.
Continued on next page