DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1520TSC-ADM (Administered Temporary Signaling Connections)
10
2000 ABORT The Administered TSC is not responding to a TSC
heartbeat inquiry.
1. Retry the test tsc-administered command at
one-minute intervals a maximum of three times.
2. If the problem continues to fail, obtain the status of
the D-channel or D-channel pair associated with the
ADMTSC via the status sig-group <group>
command. If the D-channel is INS (that is, in-service)
and the status of the ADMTSC appears to be active,
disable and enable the ADMTSC through
administration. NOTE: To disable the ADMTSC,
display the (administration) Signaling Group Form
via the change sig-group <group> command
where <group> refers to the number of the signaling
group under which the suspect TSC is administered.
Change the "Enable" field to "n." To enable the
ADMTSC, change the "Enable" field to "y."
3. Reissue the test tsc-administered command.
4. If the test fails, check the ADMTSC node on the other
side of the network to verify that the ADM TSC is
indeed active.
5. Escalate the problem.
2012 ABORT Internal System Error.
1. Reissue the test tsc-administered command at
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1 FAIL The Administered TSC is not active (far-end).
1. Reissue the test tsc-administered command.
2. Verify that the Administered TSC node on the other
side of the network is active.
3. Disable and enable the Administered TSC.
4. Retry the test tsc-administered command.
5. If test fails, escalate the problem.
Table 10-453. TEST #604 TSC Hartbeat Inquiry Test
Error
Code
Test
Result Description/ Recommendation
Continued on next page