DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-325CO-DS1 (DS1 CO Trunk)
10
2000 ABORT Response to the test request was not received within the
allowable time period.
2012 ABORT The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals for a
maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL The trunk cannot be seized for an outgoing call. This
could cause in-line failures to be reported against the
trunk (no answer would report error type 257 with
auxiliary data 57487 in the error log).
1. Verify that the Trunk Type field on the trunk
administration screen form matches the trunk type
administered on far end switch.
2. Look for DS1-BD/UDS1-BD errors in Hardware Error
Log. If present, refer to the appropriate
DS1-BD/UDS1-BD (DS1/UDS1 Trunk Circuit Pack)
Maintenance documentation.
3. Retry the test at 1-minute intervals for a maximum of
5 times.
4. If the test continues to fail, escalate the problem.
Table 10-91. TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page