Maintenance Object Repair Procedures
Page 10-430DID-DS1 (DS1 DID Trunk)
10
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
c. System Technician has busied out the trunk to out-of-service state. No
calls can be made on this trunk.
d. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
e. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57474, rotary dial rate above 12 pulses per
second; 57473, rotary dial rate below eight pulses per second. Escalate
the error.
f. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57392, no external release on PBX disconnect.
Escalate the error.
g. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57393, belated external release on PBX
disconnect. Escalate the error.
h. DS1 Interface circuit pack is out-of-service. Look for DS1-BD errors in
Hardware Error Log. Refer to the DS1-BD (DS1 Trunk Circuit Pack)
Maintenance documentation for details.
i. Error Type 2305This error indicates that a signaling change was
detected by the PBX trunk circuit pack which is inconsistent with the
present state of the trunk.
j. Port Audit and Update Test (#36) failed due to an internal system error.
Enter status trunk command to verify the status of the trunk. If the trunk is
out-of-service, then enter the release trunk command to put it back to
in-service. Retry the test command. If the test continues to abort, then
escalate the problem.