Maintenance Object Repair Procedures
Page 10-1330SYNC (Synchronization)
10
5. The following two patterns may occur when the circuit pack is either in
Active or Standby mode. The best approach to determine the mode of the
circuit pack is to use the status system system technician command.
■ Maintenance running on the Standby circuit pack is indicated by
the following pattern (yellow and green LEDs flashing): LED on 0.1
seconds, off for 0.2 seconds, on for 0.1 seconds, off for 0.4
seconds, on for 0.4 seconds, off for 0.4 seconds.
■ Green flashing and yellow flashing in a pattern different than the
previously mentioned pattern indicates that maintenance is running
on the Active circuit pack.