DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-266recycle carrier
8
recycle carrier
This command recycles power on a carrier.
Synopsis
recycle carrier location
Permissions
The following default logins may execute this command: system technician,
inads, init.
Examples
recycle carrier c
recycle carrier 01c
recycle carrier 2b
recycle carrier 3d
Description
The recycle carrier command recycles power on a specific carrier. When a
power unit is replaced in a carrier, this command must be entered to recycle the
power on that carrier. The processor carrier and its duplicate if present as
well as any EPN control carrier or an SCC carrier cannot be recycled. If a
port carrier is recycled, service is interrupted for that port carrier. If a carrier
containing an active EI is recycled, communications with that cabinet will be
disrupted. If a carrier containing an active tone-clock board is recycled, all
ports in port network will have service disrupted. For more details on
recycling and trouble shooting power units, refer to "Troubleshooting Control
Carrier Power Units" in Chapter 5, ‘‘
Routine Maintenance Procedures’’.
Defaults
The default cabinet is cabinet 1. There is no default carrier.
Parameters
location The location designates the physical location of the desired carrier.
The location consists of the cabinet number and a carrier letter. The
cabinet number is one or two digits from 1 to 3 with leading zeros
allowed. Cabinet 1 is the PPN with 2-3 referring to some optional EPN
cabinet. The carrier letter may be "b" through "e". The "b" carrier may
not be specified for SPE duplex PPNs.