DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-231CABINET (Cabinet Sensors)
10
7. Remove the fan from the fan assembly.
8. Position the replacement fan and reconnect the fan power plug.
9. Insert and tighten the retaining screws.
10. Replace the fan assembly cover or panel.
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Cabinet Sensors Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test environment P sh r 1
1 Any Cabinet
Temperature
Query Test (#122)
MINOR ON test environment P sh r 3
257 Any Cabinet
Temperature
Query Test (#122)
MAJOR ON test environment P sh r 3