DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1015PDMODULE, TDMODULE (Data Module)
10
Data Module Audits Test (#17)
This is a series of six tests that are classified as hardware audits. The processor
sends messages to the on-board microprocessor to perform the following tests.
[G1] The audits run only if the station is in-service.
7 FAIL Conference test failed on the primary information
channel. In some cases, user may not notice disruption
in service. In extreme cases, conferencing feature may
not work at all.
14 FAIL The primary information channel is not transmitting
properly. User impact may range from noticing nothing
to not being able to use this port.
15 FAIL The control channel between the processor and Digital
Line circuit pack is not transmitting properly. This can
cause a wide range of effects. The user may notice
nothing or the port may be totally unusable. This could
also disrupt other users.
1. Run circuit pack tests to check the Tone Generator
and the Tone Detector circuit packs using the test
board UUCSS short command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit
pack.
3. If the Tone Generator and Tone Detector circuit
packs are functioning properly, and the test still
fails, replace the Digital Line circuit pack.
16 FAIL The secondary information is not transmitting properly.
This can cause a wide range of effects. The user may
notice nothing or the port may be totally unusable.
1. To be sure that this is not an intermittent problem,
repeat this test up to a maximum of 10 times to
make sure it continues to pass.
2. If complaints still exist (poor data transmission),
examine the data module, connections, and wiring.
PASS Information and Control Channel Local Loop Test
passed. All channels are transmitting properly.
Table 10-290. TEST #13 Information and Control Channel
Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page