DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1285STBY-SPE (Standby SPE)
10
2023 ABORT Internal system error.
2024 ABORT The Standby SPE Maintenance/Tape Processor did not respond to an Active
SPE request to release the Standby SPE Processor to perform a function; OR
the Standby SPE Processor was released but did not carry out the requested
function and/or did not reply to the request; OR the Standby SPE Processor
was released but cannot run because the Standby SPE Memory is defective.
The communication path between the Active SPE and the Standby SPE
Maintenance/Tape Processor may have failed, or the Standby SPE
Maintenance/Tape Processor may have failed, or the Standby SPE Processor
may have failed.
1. Check for Active SPE Maintenance/Tape Processor errors and alarms.
Refer to PR-MAINT (Maintenance/Tape Processor) Maintenance
documentation and follow the prescribed procedures.
2. Check for carrier A Duplication Interface circuit pack errors and alarms.
Refer to DUPINT (Duplication Interface Circuit Pack) Maintenance
documentation and follow the prescribed procedures.
3. Check for Standby SPE Maintenance/Tape Processor errors and alarms.
Refer to PR-MAINT (Maintenance/Tape Processor) Maintenance
documentation and follow the prescribed procedures.
4. Check for Standby SPE Processor errors and alarms. Refer to PROCR
(80286 Processor Circuit Pack) Maintenance documentation and follow
the prescribed procedures.
5. Check for Standby SPE Memory errors and alarms. Refer to MEM-BD
(Memory circuit pack) Maintenance documentation and follow the
prescribed procedures.
Table 10-392. Test Result Error Codes Associated with the Standby SPE
— Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page