Maintenance Object Repair Procedures
Page 10-884MET-LINE (MET Line)
10
2020 ABORT The test did not run due to an already existing error on
the specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this
port or the circuit pack and attempt to diagnose the
already existing error.
Any FAIL This test can fail due to on-board or off-board problems.
Off-board problems of concern include EXP-INTF faults,
TDM-BUS faults, and faults associated with the tone
detectors/tone generators. Clear all off-board problems
before replacing the board. Keep in mind that a
TDM-BUS problem is usually the result of a faulty board
connected to the backplane or bent pins on the
backplane.
1. Look for EXP-INTF errors in the error log. If present,
refer to the EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present,
refer to the TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the
error log. If present, refer to the TONE-BD
Maintenance documentation and the TONE-PT
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3
are cleared. Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots.
User-reported troubles on this port should be
investigated using other port tests and examining
station, trunk, or external wiring.
Table 10-252. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation