DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1179PRI-CDR/SEC-CDR (PRI-CDR Link)
10
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to
the extension where the CDR output device connects to or opens the EIA port to
the CDR output device. If the CDR link is already up, this test is passed without
making any data call or opening the EIA port.
Table 10-358. TEST #213 Link Tear Down Test
Error
Code
Test
Result Description/ Recommendation
40 ABORT Internal system error
50 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1010 ABORT The CDR link has been busied out to out-of-service.
1. Enter the release cdr-link primary|secondary command to release
the CDR link from busyout state.
2. Retry the test cdr-link primary|secondary long command to execute
the test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The CDR link is torn down.
Continued on next page
Table 10-359. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10 ABORT Internal system error
20 ABORT Internal system error. Internal error in Maintenance Action Process (MAP).
MAP returns an error back to maintenance script (HMM). Timer expires
while waiting for the reply from MAP.
1. Retry the command at 1-minute intervals a maximum of 5 times.
30 ABORT Internal system error
1. Refer to ‘‘
Procedures for Restoring the CDR Link’’.
Continued on next page