DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-646test processor
8
For the following output example, the command "test pri-endpoint 22501" was
entered. Assume that the PRI endpoint ports for extension 22501 are in cabinet
1, carrier B, slot 20, circuit 1 to 3.
Feature Interactions
None.
test processor
This command will test the processor circuit pack.
Synopsis
test processor location
[ short | long ] clear schedule
Test No The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED."
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test pri-endpoint 22501 short page 1 of 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B2001 PE-BCHL 22501 36 PASS
01B2001 PE-BCHL 22501 255 PASS
01B2001 PE-BCHL 22501 256 PASS
01B2001 PE-BCHL 22501 257 PASS
01B2002 PE-BCHL 22501 36 PASS
01B2002 PE-BCHL 22501 255 PASS
01B2002 PE-BCHL 22501 256 PASS
01B2002 PE-BCHL 22501 257 PASS
01B2003 PE-BCHL 22501 36 PASS
01B2003 PE-BCHL 22501 255 PASS
01B2003 PE-BCHL 22501 256 PASS
01B2003 PE-BCHL 22501 257 PASS
Command Successfully Completed