Maintenance Object Repair Procedures
Page 10-1681XXX-BD (Common Port Circuit Pack)
10
Table 10-496. TEST #220 Neon Test
Error
Code
Test
Result Description/ Recommendation
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the station extension. Use the
status station command to determine the service state
of the port. If the service state indicates that the port is in
use, then the port is unavailable for certain tests. (Refer
to the "Status Commands" section in Chapter 8,
‘‘Maintenance Commands and Trouble-Clearing Aids’’
for a full description of all possible states.) You must wait
until the port is idle before retesting.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1008 ABORT Could not allocate a ringing circuit. Either all the ringing
circuits are in use, or the ringing generator is defective
or is not wired correctly.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, look for RING-GEN
errors in the Error Log. If an ABORT 1008 occurs for
this test on other circuit packs as well, then the
ringing generator may be defective or is not wired
correctly (see errors for RING-GEN). If it doesn’t
occur on port test 48 for ANL-16-L, then all four ring
phases are in use.
3. If the test to continues to abort, escalate the
problem.
Continued on next page