DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1634UDS1-BD (UDS1 Interface Circuit Pack)
10
If the 120A1 CSU Module is not physically installed, the status LEDs are always
off and this test will abort.
Table 10-477. TEST #1227 ICSU Status LEDs Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT The ICSU Status LEDs test can not be executed for the
current configuration. The test applies only to TN464F or
later UDS1 circuit packs administered for 24-channel
operation (1.544 bit rate).
1. If the circuit pack is a TN464F or later suffix UDS1
circuit pack, then retry the command.
2. If the test continues to abort, escalate the problem.
1951 ABORT The ICSU Status LEDs Test can not be executed
because a 120A1 or later suffix CSU Module is not
physically installed. If using a 120A1 CSU Module,
physically connect it to the TN464F board on the back of
the port carrier. Otherwise, ignore this abort.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2500 ABORT Internal System Error
1. Retry the command.
2. If the test continues to abort, follow normal
escalation procedures.
Continued on next page