DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-15AC-POWER
10
Table 10-7. TEST #78 AC Power Query Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the allowable time
period.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
any FAIL The Maintenance/Tape Processor in a PPN in a system without High or
Critical Reliability, the Duplication Interface circuit pack in a High or Critical
Reliability system PPN, or the EPN Maintenance circuit pack in an EPN
multicarrier cabinet system is incorrectly reporting a problem with AC
power. If this test fails, the problem is with the circuit pack and not with
AC-POWER. The suspect circuit pack, depending on the system
configuration, should be replaced and the test rerun.
PASS All that can be inferred is that the PR-MAINT (Maintenance/Tape
Processor) in a PPN in a system without High or Critical Reliability, the
DUPINT (Duplication Interface) circuit pack in a High or Critical Reliability
system PPN, or the EPN MAINT (Maintenance) circuit pack in an EPN
multicarrier cabinet system is working properly.