DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1579UDS1-BD (UDS1 Interface Circuit Pack)
10
Major alarm on the UDS1 Interface circuit pack. The Inquiry Test will be run every
10 minutes until the Major alarm is cleared. The maintenance software places all
trunks or ports on the circuit pack in the out-of-service state if the Major alarm
persists for more than 20 minutes.
When the Major alarm is cleared, the maintenance software restores all trunks or
ports on the circuit pack to their previous service state before a Major alarm
occurs.
Table 10-464. TEST #142 Major Alarm Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page