DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-52change circuit-packs
8
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If an invalid cabinet number is entered on the command line the following
message will be displayed:
"n" Identifier not assigned
Output
For the following output example, the command entered is "change circuit-packs
1" which is a n single-carrier cabinet. All five pages are shown here.
Cabinet The administered number of the cabinet.
Cabinet Layout Type of cabinet (single-carrier).
Carrier Each page of this form reports the information for a specific carrier,
this field tells the user which carrier of the cabinet that this page refers
to.
Carrier Type For each carrier - A, B, C, or D, what its function is (port, processor, or
expansion control).
Slot Lists the slot numbers from 0 - 21 depending on the type of carrier.
Code The circuit pack code (TN number). This number identifies the circuit
pack type to the system. The proper format are the letters "TN"
followed by a three digit number.
Sfx For suffix, lists the suffix if the particular circuit pack has one.
Name This field contains the alphanumeric name for the circuit pack. It is
provided to aid the user in entering the circuit pack codes.