Page 10-1545UDS1-BD (UDS1 Interface Circuit Pack)
10
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the add ds1 PCSS command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal
ID and the port.
Table 10-456. TEST #50 NPE Connection Audit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page