Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-4busyout board
8
Output
For the following output example, the command "busyout access-endpoint
22502" was entered. Assume that the access endpoint ports for extension 22502
are in cabinet 1, carrier C, slot 11, circuit 1 to 6.
Feature Interactions
If there is an active call on the specified access endpoint, the busyout command
will cause the call to drop. This command is destructive.
busyout board
This command will busyout each maintenance object on the specified board.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out.
Maintenance Name The type of maintenance object that is being busied out. For
wideband access endpoint the maintenance name for each port
is "WAE-PORT.” For single port access endpoint the maintenance
name is "TIE-DS1."
Alt. Name The alternate way of identifying the maintenance object. This field
contains the extension number of the access endpoint.
Result An indicator as to whether the object is successfully busied out.
The possible values are: PASS, FAIL and ABORT.
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be in the
"Busyout/Release Error Codes" section of this chapter.
busyout access-endpoint 22502 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1101 WAE-PORT 22502 PASS
01C1102 WAE-PORT 22502 PASS
01C1103 WAE-PORT 22502 PASS
01C1104 WAE-PORT 22502 PASS
01C1105 WAE-PORT 22502 PASS
01C1106 WAE-PORT 22502 PASS
Command Successfully Completed