Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-59change system-parameters maintenance
8
change system-parameters
maintenance
change system-parameters maintenance
The maintenance-related system parameters form specifies and displays
scheduled maintenance operations and maintenance support functions.
This form activates and deactivates INADS alarm origination when performing
repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them when you are done.
2. Change the Alarm Origination to OSS Numbers field to “neither.”
3. Change the CPE Alarm Activation Level field to “none.”
4. If daily scheduled maintenance must be prevented from starting during a
maintenance procedure, set the Start Time field to a time after the
session will end. If daily Scheduled Maintenance is already running and
needs to be shut off, set the Stop Time field to one minute after the
current time.
5. Press
Enter and verify that the screen displays the message:
Command successfully completed
NOTE:
For earlier releases of system software, disable Cleared Alarm
Notification and Restart Notification before submitting the form.
NOTE:
When finished working on the switch be sure to return all fields to
their original settings.
Examples
change system-parameters maintenance
Output
An input form displays with the following fields. Defaults for data entry fields are
listed in parentheses.