Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1118PMS-PRNT/JNL-PRNT (PMS Printer Link)
10
Error Log Entries and Test to Clear Values
Notes:
a. System Technician busied out the Journal Printer Link. The link is torn
down. Enter release command to restore the link.
b. Link Retry Test (#215) fails. Physical link cannot be set up, usually
because of hardware problems such as power off or cable disconnect.
The Aux Data field contains the Channel ID of Data Channels on Network
Control circuit pack (that is, 3 for Channel 01, 4 for Channel 02, 5 for
Channel 03, 6 for Channel 04), an Error Code 255 for the Internal system
error, or 0 which indicates that the data module connected to the PMS
Printer Link is out-of-service. Refer to ‘‘
Procedures for Restoring the PMS
Printer Link’’ section for resolution.
c. Physical link cannot be set up, usually because of hardware problems
such as power off or cable disconnect. The PMS Printer Link physical link
is down due to the following causes: cable to the printer device is
disconnected, the printer device is powered off, or the data extension
where the printer device connects to has been busied out. The Aux Data
field contains the Channel ID of Data Channels on Network Control circuit
pack (that is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for
Channel 04). Check the connectivity of wire and cable among wall jacket,
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Both PMS Printer and Journal Printer are administered to the same extension, and the printer is not
connected. Refer to the ‘‘
Procedures for Restoring the PMS Printer Link’’ section for resolution.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
Table 10-329. PMS-PRNT/JNL-PRNT Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test journal
wakeup-log|pms-log sh
18 (a) 0 busyout journal
wakeup-log/
pms-log
WARNING OFF release journal
wakeup-log|pms-log
257 (b) 0,
3 to 6
255
Link Retry Test
(#215)
MINOR/
WARNING
2
OFF test journal
wakeup-log|pms-log 1
513 (c) 0,
3 to 6
255
test journal
wakeup-log|pms-log
769 (d)