DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-656test signaling-group
8
If the specified group identifier is not administered, the following message is
displayed:
No signaling group assigned
If no tests can be found for the associated MO, the following message is
displayed:
No tests for this MO
If the software data cannot be sent to the SAT, the following message is
displayed:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command "test
signaling-group 1" was entered.
Port The signaling group number (1-8) of the signaling group that is
being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name Not Applicable.
Test No The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO [for example, see MO section on
"ISDN-SGR (ISDN-PRI Signaling Group)"].