Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-998OPS-LINE (DS1 OPS Line)
10
1004 ABORT The port has been seized by a user for a valid call. Use
the status station command to determine when the port
is available for testing.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1005 ABORT Test failed due to incompatible configuration
administered in station administration.
1. Verify the station administration is the station
assigned to Port 24 of the DS1 Interface circuit pack
while common channel signaling is specified.
1006 ABORT The test was aborted because the station is out of
service. This condition may be accompanied by an error
type 18 entry in the error log. You may want to determine
why the station was taken out of service. (When stations
are taken out of service by maintenance software, the
problems that led up to that must be cleared.)
1. Use the status station command to check the state
of the port. If the port is indeed out of service, enter
the release station command to bring the station
back into service.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort, and the station is in the
in-service/idle state, escalate the problem.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in Hardware Error Log. If
present, refer to the DS1-BD (DS1 Interface Circuit
Pack) Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
Table 10-288. TEST #312 DS1OPS Switchhook Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page