DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1671XXX-BD (Common Port Circuit Pack)
10
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system. This error type is not applicable to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same
slot as the error indicates) to resolve this error. Or, if the circuit pack is in
the system and the red LED is on, follow the instructions for "Red (alarm)"
in the ‘‘
Control and Port Circuit Pack Status LEDs’’ section in Chapter 7,
‘‘LED Interpretation’’ (See also the ‘‘Handling Control Circuit Packs’’
section in Chapter 5, ‘‘
Routine Maintenance Procedures’’)
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board PCSS.
c. The circuit pack has been logically administered but not physically
installed. The alarm should clear when the circuit pact is installed.
If the circuit pack is already installed:
1.Run test board PCSS long and look at any test failures or error codes
generated.
2.If the test does not clear error 23, then execute reset board PCSS and
run the long test again.
3.If the reset/test does not clear error 23, replace the circuit pack.
d. This error applies only to the Maintenance/Test circuit pack (TN771B or
TN771C). The error indicates that the hardware associated with the
Analog Trunk Testing port of the circuit pack failed to initialize. This port is
not used in G3iV1.1-286 or G3iV2-386. Note, however, that when this error
occurs, the Maintenance/Test circuit pack may report an invalid vintage.
Although this error is not service-affecting, the Maintenance/Test circuit
pack should be replaced.
e. A wrong circuit pack is inserted in the slot where this circuit pack is
logically administered. To resolve this problem, either remove the wrong
circuit pack and insert the logically administered circuit pack OR use the
change circuit-pack command to readminister this slot to match the
circuit pack inserted.
f. This error applies to the Maintenance/Test circuit pack (TN771D), Tone
Detector (TN748B, TN748C, or TN748D), and Call Classifier (TN748)
circuit packs. For the Maintenance/Test circuit pack, the error indicates
that there is more than one Maintenance/Test circuit pack in the port
network. For the Tone Detector or Call Classifier packs, the error indicates
that there are more than 10 circuit packs in the system. Remove the circuit
pack against which the error is logged.