Maintenance Object Repair Procedures
Page 10-1475TIE-TRK (Tie Trunk)
10
1002 ABORT The system could not allocate timeslots for the test. The
system may be under heavy traffic conditions or it may
have timeslots out of service due to TDM bus errors.
Refer to TDM Bus Maintenance to diagnose any active
TDM bus errors.
1. If system has no TDM bus errors and is not handling
heavy traffic, repeat test at 1 minute intervals for a
maximum of 5 retries.
2. If the test continues to abort escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use
status trunk to determine when the port is available for
testing.
1. Retry the command at 1 minute intervals for a
maximum of 5 retries.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1005 ABORT Trunk has been administered as incoming-only;
transmission tests can only be run on outgoing trunks.
1115 ABORT The near end test line on the TN771 circuit pack could
not be allocated.
1. Verify that the TN771 circuit pack is in service and
that port 1 is administered and in service with the
status port command.
2. retry the command at 1 minute intervals for a
maximum of 5 retries.
3. If the test continues to abort escalate the problem.
1900 ABORT The test completion message was not received from the
TN771 circuit pack.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
Table 10-447. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation