Maintenance Object Repair Procedures
Page 10-536DS1-BD (DS1 Interface Circuit Pack)
10
4. A list configuration command shows that the circuit pack and
ports are properly installed.
The circuit pack is isolated from the system and all trunks of this circuit
pack are placed into the out-of-service state. The system will try to restore
the circuit pack within 15 minutes. When no faults are detected for 15
minutes, the DS1 Interface circuit pack is restored to normal operation. All
trunks of the DS1 Interface circuit pack are then returned to the in-service
state. If the error recurs after 15 minutes, then replace the circuit pack.
r. For later releases of G3V4 and beyond, only error 3073 will show that this
board is receiving Slips and the AUX data shows the last Slip count that
was reported.
s. For later releases of G3V4 and beyond, only error 3329 will show that this
board is receiving misframes and the AUX data shows the last misframe
count that was reported.
t. This error is not service-affecting and can be ignored.
u. Error 3900 is used to give status information on a CPE Loopback Jack
Test. The value in the Aux Data field indicates the status of the loopback
test.
v. Error 3901 is used to give status information on a Far CSU Loopback Test.
The value in the Aux Data field indicates the status of the loopback test.
w. Error 3902 is used to give status information on a One-Way Span Test. The
value in the Aux Data field indicates the status of the span test.
x. Error type 3999 indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
error type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If error type 1538 is not present, then
1
Test is currently running.
2
Test failed because loopback could not be activated.
3
Test failed because test pattern could not be detected.
4
Test has been terminated.
1
Test is currently running.
2
Test failed because loopback could not be activated.
3
Test failed because test pattern could not be detected.
4
Test has been terminated.
1
Test is currently running.
2
Test has failed because test could not be activated.
3
Test pattern was not received from the far end.
4
Test has been terminated.