DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1039PE-BCHL (PRI Endpoint Port)
10
Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the UDS1
interface circuit pack to ensure that the port’s translation is correct. The port audit
operation verifies the consistency of the current state of the port that is kept in the
UDS1 interface circuit pack and in the switch software.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections.
1. Replace the circuit pack. Even though wideband calls do not use the
conferencing feature on the NPE, this failure indicates problems with
the circuit pack hardware.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated by using the other port tests
and by examining the terminal adapter or the external wiring.
Table 10-298. TEST #36 Audit and Update Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The test failed due to Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-297. TEST #7 Conference Circuit Test Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page