Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-39busyout station
8
Parameters
Help Messages
If the system technician presses HELP after entering "busyout station," the
following message will be displayed:
Enter extension for an assigned station
Error Messages
If the format of the extension is incorrect, the following error message will be
displayed:
Extension invalid
If the specified extension is not administered, then the following message will be
displayed:
Extension not assigned
If the specified extension does not belong to a station or attendant console, the
following message will be displayed:
Extension exists but assigned to a different object
If the station port resides on an EPN that is unavailable, the following message
will be displayed:
EPN is not available
If the station port resides on a board that is not inserted in the system, the
following message will be displayed:
Board not assigned
If the station port resides on a board that is part of the SCI link, the following
message will be displayed:
Cannot busyout/release part of SCI link
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
extension An extension number associated with the desired voice terminal. The
number of digits in an extension is determined by a dial-plan.