DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-432DID-DS1 (DS1 DID Trunk)
10
1000 ABORT System resources required to run this test were not
available.
The port may be busy with a valid call. Use the display
port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the Error Log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1001 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM BUS error.
Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM Bus errors.
1. If system has no TDM-BUS errors and is not
handling heavy traffic, repeat test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-121. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page