DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-905MET-LINE (MET Line)
10
PASS Hybrid Station Ringer Update passed.
1. If complaints still exist, investigate using other circuit
pack tests, and by examining the terminal, wiring,
and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, check to ensure that
there is a valid board inserted.
Table 10-258. TEST #62 MET Line Ringer Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page