Maintenance Object Repair Procedures
Page 10-345CO-TRK (CO Trunk)
10
Table 10-96. TEST #6 NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port was seized by a user for a valid call. Use the
display port UUCSSpp command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the Error Log table for a description of this error
and required actions). The port may be locked up.
Check the CO wiring, check for excessive loop
current, and check the trunk translations. (If the trunk
is translated incorrectly, this test will abort.)
2. If the port status is idle, busyout and release the
trunk, and then retry the command at 1 minute
intervals for a maximum of 5 times.
3. If the test still aborts, replace the circuit pack.
4. If the test continues to abort, escalate the problem.
1001 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page