DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-410DATA-CHL (Network Control Data Channel)
10
2011
2012
2013
2016
2017
2020
2022
2051
ABORT Refer to STBY-SPE (Standby SPE) Maintenance documentation for a
description of these error codes.
40
2000
2003
2004
FAIL In the case of Error Code 40, the Local Loop Back Test failed because the
data received over the connection did not match the data sent over the
connection (data was corrupted). In the case of Error Code 2000, 2003,
and 2004, the Local Loop Back Test failed because the data looped over
the connection was not received (data was lost).
1. Determine which of the DATA-CHLs are in use for some other function
(that is, PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT,
PMS-LINK or secondary administration terminal connection) as
described previously in the "Status of Network Control Data Channels"
section.
Table 10-112. TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page