DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1569UDS1-BD (UDS1 Interface Circuit Pack)
10
2000 ABORT Response to the test was not received within the
allowable time period. This may be due to hyperactivity.
Error type 1538 in the error log indicates hyperactivity.
The hyperactive circuit pack is out of service and one or
more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as test 138 and test 139)
are aborting with error code 2000.
2. The tests run on the ports of this circuit pack are
returning a no board result.
3. A ’busyout’ or a ’release’ command has no affect on
the test results.
4. A ’list config’ command shows that the circuit pack
and the ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is
isolated from the system, and all of the trunks for
this circuit pack are placed into the out of service
state. The system will try to restore the circuit pack
within 15 minutes. When no faults are detected for
15 minutes, the UDS1 interface circuit pack is
restored to normal operation. All of the trunks for
the UDS1 interface circuit pack are then returned
to the in service state. Hyperactivity is often
caused by the associated facility. In such a case,
faults (such as slips, misframes, or blue alarms)
would be entered in the error log. In addition,
many hardware errors would be logged against
the associated trunk circuits. If the facility is OK
and the error occurs again after 15 minutes,
replace the circuit pack.
Table 10-462. TEST #140 Red Alarm Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page