Maintenance Commands and Trouble-Clearing Aids
Page 8-234list testcalls
8
Help Messages
If the system technician presses HELP after entering "list testcalls", the following
message is displayed:
Please enter one of the following object command words:
detail summary
Or press CANCEL to cancel the command
If the system technician presses HELP after entering "list testcalls detail", the
following message is displayed:
Enter [[’grp’ x],[’to-grp’ x],[’mem’ x],[’to-mem’ x] or [’port’ x]],
[[’result’ x] or [’not-result’ x]],[’count’ x],[’print’ or ’schedule’]
If the system technician presses HELP after entering "list testcalls summary", the
following message is displayed:
Enter [[’grp’ x],[’to-grp’ x],[[’count’ x],
[’print’] or [’schedule’]
to-mem
member
number
This option is used to specify that measurements for all trunk group
members from 1 to the specified "to-mem" trunk group member are
displayed. When used with the "mem" option, this option is the ending
trunk group member in a range of user specified trunk group
members.
port location This option is used to specify that measurements for a specific trunk
circuit (port) are displayed.
result result
identifier
This option is used to filter out all measurement results that do not
match the user specified result (i.e. only measurement results that
match the user specified result are displayed). Examples of results are
pass, marg, fail, etc.
not-result
result
identifier
This option is used to filter out all measurement results that do match
the user specified result (i.e. only measurement results that do not
match the user specified result are displayed). Examples of results are
pass, marg, fail, etc.
count count
number
This option is used to specify (limit) the number of records displayed.
print This will cause the report to be printed if a printer is linked to the SAT.
schedule When the "schedule" option is specified, the command is validated
and then a scheduling form is displayed to allow the technician to
schedule execution of the command. The command is then placed in
the command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [1] for more details.