DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-840ISDN-TRK (DS1 ISDN Trunk)
10
8 ABORT There is a problem with the DS1 interface circuit pack.
1. Refer to DS1-BD (DS1 Interface Circuit Pack).
1004 ABORT B channel in use.
1. Determine if a call is active on this DS1 ISDN Trunk via the status
trunk
2. When the service state indicates in-service/idle, retry the test.
1005 ABORT Bad Configuration (that is, no Maintenance/Test circuit pack)
Issue the test trunk <trunk Group/trunk member> command and make
sure there is a DATA-CHL (NETCON channel) administered.
1018 ABORT Test call is disabled.
1. Enable Maintenance on the Trunk Group form.
1019 ABORT Another Test call is in progress.
1. Issue the list isdn-testcall command to locate the test call.
2. Issue the status isdn-testcall command to find out the duration and
start time of the test call.
3. Issue the clear isdn-testcall command to stop the test call from
running.
1020 ABORT There is a problem with DS1 Interface Circuit Pack.
1. Refer to the DS1-BD (DS1 Trunk circuit pack).
1024 ABORT Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the
Maintenance/Test circuit pack.
2. Retry the test.
1113 ABORT The signaling link has failed. Therefore, the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #255 (Signaling Link State Check Test).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116 ABORT The switch could not appropriately change the ISDN service state.
1. Determine if a call is active on this DS1 ISDN Trunk (use the status
trunk
2. If not, check the Error and Alarm Logs for problems with this ISDN-TRK
(DS1 ISDN Trunk) MO.
Table 10-237. TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page