Maintenance Object Repair Procedures
Page 10-958M/T-ANL (Maintenance/Test Analog Port)
10
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1 minute intervals a maximum
of 3 times.
2. If the test continues to abort, escalate the problem.
7 FAIL Conference test failed on the primary information
channel.
1. Run the circuit pack tests to check the Tone/Clock
(TONE-BD) circuit pack and the Tone Detector
circuit pack via the test board PCSS command.
2. Resolve any problems that are detected on the
Tone/Clock (TONE-BD) circuit pack or Tone
Detector circuit pack. See the section on Tone
Generator circuit pack.
3. If the Tone/Clock and Tone Detector circuit packs
are functioning properly, and the test still fails,
replace the Maintenance/Test circuit pack.
14 FAIL The primary information channel is not transmitting
properly. User may not notice any interruption in service
or may not be able to use this port.
1. Run the circuit pack tests to check the Tone
Generator circuit pack and the Tone Detector circuit
pack using test board PCSS.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit pack.
See the section on Tone Generator circuit pack.
3. If the Tone Generator and Tone Detector circuit
packs are functioning properly, and the test still fails,
replace the Maintenance/Test Circuit Pack.
PASS The Maintenance/Test Analog Port analog trunk testing
capability is operating correctly.
Table 10-274. TEST #13 Analog Port Digital Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page