DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1396TDM-BUS (TDM Bus)
10
!
WARNING:
This command removes power and returns power to the designated
Medium cabinet port carrier. Thus, any other circuit packs on this carrier is
also temporarily taken out-of-service.
Error Log Entries and Test to Clear Values
NOTE:
For TDM-BUS, an ON-BOARD alarm refers to a problem with the TDM-BUS
itself.
Notes:
a. The TDM Bus has been busied out by the technician. The error retires
when the technician releases the TDM Bus.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-420. TDM Bus Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test tdm
1 0 Control Channel Test
(#296)
MINOR ON test tdm P r 3
18 (a) 0 busyout tdm PC WARNING ON release tdm PC
35 (b) 0-1 TDM Bus Corruption MINOR ON set tdm PC
257 (c) 0 none MAJOR ON
513 (d) Any Idle Time Slot Test (#294) MINOR ON test tdm P r 3
769 (e) Any Idle Time Slot Test (#294) WARNING ON test tdm P r 3
769 (f) Any Idle Time Slot Test (#294) (see Notes)
1025 Any
3872 (g) Any none
3873 (g) Any none
3874 (g) Any none
3877 (g) Any none